{"id":692,"date":"2024-08-27T15:18:42","date_gmt":"2024-08-27T06:18:42","guid":{"rendered":"https:\/\/www.ecginc.co.jp\/?page_id=692"},"modified":"2024-08-28T16:46:32","modified_gmt":"2024-08-28T07:46:32","slug":"option","status":"publish","type":"page","link":"https:\/\/www.ecginc.co.jp\/en\/products\/option\/","title":{"rendered":"DWX\u30b7\u30ea\u30fc\u30ba \u30aa\u30d7\u30b7\u30e7\u30f3\u54c1"},"content":{"rendered":"\r\n<div class=\"read\">\r\n<p>The following is a partial list of options for the DWX series.<br>\r\nECG-KOKUSAI can customize test functions and modify test equipment to meet your needs.<\/p>\r\n<\/div>\r\n\r\n\r\n\r\n<article>\r\n<div class=\"ctn-flex\">\r\n\r\n<div class=\"box\">\r\n\t<div class=\"box-inner\">\r\n\t\t<figure><img decoding=\"async\" src=\"\/img\/product\/option\/img-01.jpg\"><\/figure>\r\n\t\t<h3>Ethernet adapter (4P-2303A)<\/h3>\r\n\t\t<div class=\"inner\">\r\n\t\t\t<p> This is a TCP\/IP to serial conversion adapter that enables remote control of DWX via a network connection. The included control software (DW-AssisWin) allows easy control from a Windows PC.<\/p>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div>\r\n\r\n<div class=\"box\">\r\n\t<div class=\"box-inner\">\r\n\t\t<figure><img decoding=\"async\" src=\"\/img\/product\/option\/img-02.png\"><\/figure>\r\n\t\t<h3>CF Card (MFD10P-001GV)<\/h3>\r\n\t\t<div class=\"inner\">\r\n\t\t\t<p>The Compact Flash memory card (CF card) can be used as an expansion memory for the main unit&#8217;s memory, as well as for saving and reading out master waveforms in page units. It is also possible to save log data of test results and screenshots of the test screen.<\/p>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div>\r\n\r\n<div class=\"box\">\r\n\t<div class=\"box-inner\">\r\n\t\t<h3>Interlock function Additional options<\/h3>\r\n\t\t<div class=\"inner\">\r\n\t\t\t<p>Add hard interlock function. Combined with safety devices such as light curtains, etc., this function improves safety.<\/p>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div>\r\n\r\n<div class=\"box\">\r\n\t<div class=\"box-inner\">\r\n\t\t<h3>PNP conversion specification Additional option<\/h3>\r\n\t\t<div class=\"inner\">\r\n\t\t\t<p>The external control section of the standard specification is NPN specification, but it can be changed to PNP specification.<\/p>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div>\r\n\r\n<div class=\"box\">\r\n\t<div class=\"box-inner\">\r\n\t\t<h3>BDV test function Additional option<\/h3>\r\n\t\t<div class=\"inner\">\r\n\t\t\t<p>Option to add BDV (Breakdown Voltage) test function.<br>\r\nThe test voltage is applied to the coil under test, starting from a low voltage and gradually increasing, and breakdown is detected by AREA and Laplacian judgment.<\/p>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div>\r\n\r\n<div class=\"box\">\r\n\t<div class=\"box-inner\">\r\n\t\t<h3>CF Software<\/h3>\r\n\t\t<div class=\"inner\">\r\n\t\t\t<p>Simple communication software for saving master waveform data, log data, and screenshots of the test screen to a PC.<\/p>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div>\r\n\r\n<div class=\"box\">\r\n\t<div class=\"box-inner\">\r\n\t\t<h3>Other Special Specifications<\/h3>\r\n\t\t<div class=\"inner\">\r\n\t\t\t<p>Please contact us if you have a special test object or test method.<br>\r\nWe can flexibly respond to your testing needs by modifying software and hardware.<br>\r\nExample: Calibration for a specific coil, modification of IO signal output to suit automated equipment, etc.<\/p>\r\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div>\r\n\r\n<\/div>\r\n<\/article>\r\n","protected":false},"excerpt":{"rendered":"<p>The following is a partial list of options for the DWX series. ECG-KOKUSAI can customize test functions and modify test equipment to meet your needs. Ethernet adapter (4P-2303A) This is a TCP\/IP to serial conversion adapter that enables remote control of DWX via a network connection. The included control software (DW-AssisWin) allows easy control from [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":674,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_locale":"en_US","_original_post":"https:\/\/www.ecginc.co.jp\/?page_id=25","footnotes":""},"class_list":["post-692","page","type-page","status-publish","hentry","en-US"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.ecginc.co.jp\/wp-json\/wp\/v2\/pages\/692","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ecginc.co.jp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ecginc.co.jp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ecginc.co.jp\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ecginc.co.jp\/wp-json\/wp\/v2\/comments?post=692"}],"version-history":[{"count":4,"href":"https:\/\/www.ecginc.co.jp\/wp-json\/wp\/v2\/pages\/692\/revisions"}],"predecessor-version":[{"id":872,"href":"https:\/\/www.ecginc.co.jp\/wp-json\/wp\/v2\/pages\/692\/revisions\/872"}],"up":[{"embeddable":true,"href":"https:\/\/www.ecginc.co.jp\/wp-json\/wp\/v2\/pages\/674"}],"wp:attachment":[{"href":"https:\/\/www.ecginc.co.jp\/wp-json\/wp\/v2\/media?parent=692"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}